Tel:06021-58830-11

Contact us

06021-58830-11
Mod:06021-58830-11
Fax:06021-58830-0
Add:Zeppelinstr. 5, 63741 Aschaffenburg, Germany

HPLC Columns

Target™ SEC

summary
Target™ sec is a full range of high performance volume exclusion chromatographic columns. According to the principle of dynamic volume, it is used for the chromatography of many different biomacromolecules
Separation. The product is a high-performance sec volume exclusion separation medium developed by independent innovation technology. It is based on monodisperse porous silica gel and has pore channels
The structure is specially designed and coated with neutral hydrophilic layer on the surface of silica gel to minimize the interaction between analyte and stationary phase. It is widely used in biology
Pharmaceutical, medical and scientific research.
Characteristic advantages
The non-specific adsorption of protein was very low, resulting in symmetrical peak shape and high recovery rate;
Excellent mechanical strength ensures high column efficiency and separation;
Low column loss represents long life;
There are a wide range of products with different pore size parameters, which can meet the separation requirements of proteins, polypeptides, oligonucleotides, cephalosporins and polysaccharides.
Minimal nonspecific adsorption
The retention time of lysozyme (sample) on other SEC columns increased significantly with the decrease of buffer concentration in mobile phase, which had strong non-specific adsorption effect of ion exchange. However, the influence on targettm SEC column was very small, which made the protein sample analysis data more accurate and real.

Technical parameters of target™  SEC column
model Target-SEC150 Target-SEC300 Target-SEC500 Target-SEC1000
Material Science Surface bonded hydrophobia silica gel Hydrophobia,surface bonding Silica gel of film Hydrophobia,surface bonding Silica gel of film hydrophobia surface bonding Silica gel of film
Particle size 5µm 5µm 5µm 5µm
aperture (Å) 150 300 500 1000
Protein molecular weight range(A) 2K-150K 10K-1000K 20K-2000K 50K-10000K
Molecular weight range of polyethylene glycerin(A) 0.1K-15K 1K-100K 5K-20K 10K-100K
Molecular weight range of dextrose(A) 1K-50K 5K-150K 20K-500K 50K-2000K
fstability 2-8 2-8 2-8 2-8
Back pressure 5000Psi 5000psi 5000psi 5000psi
Salt concentration range 20M-2M 20M-2M 20M-2M 20M-2M
temperature 45℃ 45℃ 45℃ 45℃
application area Small,molecule,protein,peptide,,nondeductible,saccharine,and,phallocentric,polymer Protein,antibody,And,polymer Protein, antibody And polymer Protein, antibody, vaccine And polymer
Mobile phase compatibility Common buffer  And organic solvents Common buffer And organic solvents Common buffer And organic solvents Common buffer And organic solvents

Some applications                                                                                                                                                                                                       

Chromatographic column:
1、Target-SEC500 5um 4.6*300mm
2、Target-SEC300 5um 4.6*300mm
3、Target-SEC150 5um 4.6*300mm
Mobile phase:150mM phosphate buffered saline (pH6.8)
Current Speed:0.4ml/min
Column temperature:30℃
Injection volume:5ul
Wavelength:UV@280nm
Sample:
1、Thyroglobulin(0.5mg/ml), 670KD
2、Conalbumin(1mg/ml), 75KD
3、Ribonuclease A(1mg/ml), 13.7KD
4、Uracil(0.1mg/ml), 112D
2. Fusion protein

Chromatographic column:Target-SEC500 5um 4.6*300mm
Mobile phase:150mM phosphate buffered saline (pH6.8)
Current Speed:0.4ml/min
Column temperature:30℃
Injection volume:5ul
Wavelength:UV@280nm
Sample:Fusion Protein(1mg/ml)
3. Polyclonal antibody (IgG1)

Chromatographic column:Target-SEC300 5um 4.6*300mm
Mobile phase:150mM phosphate buffered saline (pH6.8)
Current Speed:0.4ml/min
Column temperature:30℃
Injection volume:5ul
Wavelength:UV@280nm
Sample:IgG1(2.5mg/ml)
Atlas:1、IgG1  2、IgG1 Aggregate
4. Polyclonal antibody (IgG4)

Chromatographic column:Target-SEC500 5um 4.6*300mm
Mobile phase:150mM phosphate buffered saline (pH6.8)
Current Speed:0.4ml/min
Column temperature:30℃
Injection volume:5ul
Wavelength:UV@280nm
Sample:IgG4(2.5mg/ml)
Atlas:peak1:IgG4 
peak2-6:IgG4 Aggregates
5. Human serum albumin and

Chromatographic column:Target-SEC300 5um 4.6*300mm
Mobile phase:150mM phosphate buffered saline (pH6.8)
Current Speed:1.0 ml/min
Column temperature:30℃
Injection volume:10ul
Wavelength:UV@210nm
Sample:Human albumin aqueous solution
Atlas:1、Human serum albumin
2、Human albumin dimer
3、Human albumin polymer    
6. Examination of related substances II in Cefodizime Sodium (method 2015 of Chinese Pharmacopoeia)


Chromatographic column:Target-SEC150 5um 7.8*300mm
Mobile phase:phosphate buffered saline (pH7.0):Acetonitrile(95:5)
Current Speed:1.0 ml/min
Column temperature:30℃
Injection volume:20ul
Wavelength:UV@231nm
Sample:Cefodizime sodium(0.5mg/ml)
Atlas:peak1:Cefodizime sodium
peak2-5:Cefodizime sodium polymer
7. Ceftriaxone sodium polymer test (G10 highly effective alternative sec method in Chinese Pharmacopoeia 2015)

Chromatographic column:Target-SEC150 5um 7.8*300mm
Mobile phase:phosphate buffered saline (pH7.0)
Current Speed:1.0 ml/min
Column temperature:30℃
Injection volume:20ul
Wavelength:UV@231nm
Sample:Ceftriaxone sodium
Atlas:peak1:Ceftriaxone sodium
peak2-5:Ceftriaxone sodium polymer
Target sec series product specifications

product

Pore Size

Particle size

Specifications

Part number

Target-SEC150

150A

5um

 7.8*300mm

311340-7830

Target-SEC150

150A

5um

 4.6*300mm

311340-4630

Target-SEC300

300A

5um

 7.8*300mm

311350-7830

Target-SEC300

300A

5um

 4.6*300mm

311350-4630

Target-SEC500

500A

5um

 7.8*300mm

311360-7830

Target-SEC500

500A

5um

 4.6*300mm

311360-4630

                                 
Chromatographic column selection tips: the 7.8 mmid SEC column is the traditional common specification. If the 4.6 mmid SEC column is selected, it can have higher sensitivity under the condition of limiting the sample size, and can save solvent consumption for your laboratory, which is more economical and environmental friendly.
                             
                                    

Before: Target-HIC

Before:Target™ Bio-IEX

Back
Contact Feedback
Tel:06021-58830-11
Sitemap( Google
Copyright:MS Technologies Tel:06021-58830-0  Fax:06021-58830-11    Add:Zeppelinstr. 5, 63741 Aschaffenburg, Germany

MS Technologies