Tel:06021-58830-11

Contact us

06021-58830-11
Mod:06021-58830-11
Fax:06021-58830-0
Add:Zeppelinstr. 5, 63741 Aschaffenburg, Germany

HPLC Columns

Target-Silica

●Target-Silica is based on silica gel with high purity and good mechanical stability. Through a unique surface activation method, a controllable silica surface structure is obtained, thus ensuring excellent inter column repeatability.

● There is no organic layer on the activated silica surface of target silica, which ensures the stability of target silica filler. The filler is a uniform spherical particle with pore diameter of 110A, 200Aand 300A, specific surface area of 300m2 /g, 200m2/g and 100m2/g respectively, and pH range of 2-8.

● The Target-Silica column bed density obtained by using the unique homogenate filling technology is uniform and stable, so it can ensure the highest column efficiency. Target silica column is particularly suitable for the separation of polar and hydrophilic compounds with high selectivity. Because of the polar silanol group in HP silica packing, the retention of most nonpolar organic compounds will be very small.

● Target-Silica column has a good separation effect in organic solvent or mixed solution of water and organic solvent (such as methanol, acetonitrile). This column is especially suitable for the separation of polar and basic organic compounds such as vitamins, steroids and drugs.

● Target-Silica has no organic layer, so it has excellent chemical stability and is especially suitable for the confirmation of many analytes. The surface of the filler has been activated, which can provide the compounds with the polar groups of hydrophilic interaction and the charged si-o-groups of electrostatic interaction, with the characteristics of high selectivity and high separation efficiency. Target silica has no organic layer and avoids the degradation of bonding phase. Separation can be carried out in a non-polar solvent such as hexane, or in a polar solvent such as an acetonitrile water mixture.

Vitamin E test chart   Spectrum:


Chromatographic conditions:

Column:Target-Silica,5µm, 4.6 x 250 mm 

Mobile phase:n-Heptane : Ethyl acetate = 97 : 3 ( v/v )

Flow rate:1.0mL/min

Temperature:Room temperature

Detection:UV 280 nm

Injection volume:10µL

Sample:Alpha-tocophenol (vitamin E)

Product specifications
Product      model  Particle size                  Specifications  Part number 
Target-Silica 3um 50mm 2.1mm 312213-21005
Target-Silica 3um 100mm 2.1mm 312213-21010
Target-Silica 3um 150mm 2.1mm 312213-21015
Target-Silica 3um 150mm 4.6mm 312213-46015
Target-Silica 3um 250mm 4.6mm 312213-46025
Target-Silica 5um 150mm 4.6mm 312215-46015
Target-Silica 5um 250mm 4.6mm 312215-46025
Target-Silica 10um 150mm 21.2mm 312210-21215
Target-Silica 10um 150mm 30mm 312210-30015
Target-Silica 10um 250mm 10mm 312210-10025
Target-Silica 10um 250mm 21.2mm 312210-21225
Target-Silica 10um 250mm 30mm 312210-30025
Target-Silica(II) 3um 50mm 2.1mm 313313-21005
Target-Silica(II) 3um 100mm 2.1mm 313313-21010
Target-Silica(II) 3um 150mm 2.1mm 313313-21015
Target-Silica(II) 3um 150mm 4.6mm 313313-46015
Target-Silica(II) 3um 250mm 4.6mm 313313-46025
Target-Silica(II) 5um 150mm 4.6mm 313315-46015
Target-Silica(II) 5um 250mm 4.6mm 313315-46025
Target-Silica(II) 5um 150mm 21.2mm 313315-21215
Target-Silica(II) 5um 150mm 30mm 313315-30015
Target-Silica(II) 5um 250mm 10mm 313315-10025
Target-Silica(II) 5um 250mm 21.2mm 313315-21225
Target-Silica(II) 5um 250mm 30mm 313315-30025
Target-Silica(II) 10um 150mm 21.2mm 313310-21215
Target-Silica(II) 10um 150mm 30mm 313310-30015
Target-Silica(II) 10um 250mm 10mm 313310-10025
Target-Silica(II) 10um 250mm 21.2mm 313310-21225
Target-Silica(II) 10um 250mm 30mm 313310-30025
 

 * If you need other specifications that are not in this list, please contact your sales representative.

Before:Target -NH2

Before:Target-CN

Back
Contact Feedback
Tel:06021-58830-11
Sitemap( Google
Copyright:MS Technologies Tel:06021-58830-0  Fax:06021-58830-11    Add:Zeppelinstr. 5, 63741 Aschaffenburg, Germany

MS Technologies