Tel:06021-58830-11

Contact us

06021-58830-11
Mod:06021-58830-11
Fax:06021-58830-0
Add:Zeppelinstr. 5, 63741 Aschaffenburg, Germany

HPLC Columns

Targt-HIC

Overview
 
● The Target-HIC series of hydrophobic interaction chromatography columns are primarily used for the separation of proteins, oligonucleotides, and peptides. They are composed of non-porous PS/DVB particles bonded with butyl ligands, featuring two types of ligands with varying hydrophobicity from low to high (butyl and phenyl). The non-porous, narrowly distributed hydrophobic particles enable high-efficiency separation of proteins such as monoclonal antibodies (MAbs), antibody-drug conjugates (ADCs), and related protein fragments of DNA and oligonucleotides.
 
● The packing material for each batch is manufactured under a strict quality management system and quality-controlled using relevant biomolecules (e.g., IgG monoclonal antibodies) to ensure separation performance and batch-to-batch consistency.
 
Features
 
● High column efficiency and high resolution
● Wide pH range: 2 – 8
● Particularly suitable for the separation and analysis of monoclonal antibodies and their antibody-drug conjugates (ADCs)
● Higher pressure resistance stability, capable of withstanding higher flow rates and longer column lengths
● Good alkali resistance and long service life


Protein separation

Column:Target HICb 5μm 4.6x100 mm                                  
Mobile phase:A: 2.0 M (NH4)2 SO4 in 100 mM phosphate
buffffer, pH7.0  B: 100 mM phosphate buffffer, pH7.0
Gradient Elution: 0~100%min     
Flow rate:1.0 mL/min
Temperature:30 ℃     
Injection volume:10 μL
Detection:UV 280 nm



Cysteine-conjugated monoclonal antibody

Column: Target HICb 5μm 4.6x100 mm                                    
Mobile phase:A: 2.0 M (NH4)2 SO4 in 100 mM   phosphate buffffer, pH7.0 
B)100 mM phosphate buffffer, pH7.0      C)Isopropanol                                             
Gradient Elution:0-75%A, 25-75%B ,0-25% 20min  

Flow rate:1.0 mL/min   
Temperature:30 ℃                                                   
Injection volume:10 μL   
Detection:
UV 280 nm
Sample: Cysteine conjugated ADC (~1 mg/mL in mobile phase A)  




  Ordering Information

               Model Particle Size
(μm)
Length
(mm)
Inner Diameter
(mm)
Order No.
Target-HICb(丁基) 5um 50mm 4.6mm 75005-4605
Target-HICb(丁基) 5um 100mm 4.6mm 75005-4610
Target-HICb(丁基) 5um 250mm 4.6mm 75005-4625
Target-HICp(苯基) 5um 50mm 4.6mm 77005-4605
Target-HICp(苯基) 5um 100mm 4.6mm 77005-4610

Contact Feedback
Tel:06021-58830-11
Sitemap( Google
Copyright:MS Technologies Tel:06021-58830-0  Fax:06021-58830-11    Add:Zeppelinstr. 5, 63741 Aschaffenburg, Germany

MS Technologies