Target™ SEC
Target™ SEC is a full range of high performance volume exclusion chromatographic columns. According to the principle of dynamic volume, it is used for the chromatography of many different biomacromolecules Separation. The product is a high-performance sec volume exclusion separation medium developed by independent innovation technology. It is based on monodisperse porous silica gel and has pore channels ;T he structure is specially designed and coated with neutral hydrophilic layer on the surface of silica gel to minimize the interaction between analyte and stationary phase. It is widely used in biology Pharmaceutical medical and scientific research.Characteristic advantages
1) The non-specific adsorption of protein was very low, resulting in symmetrical peak shape and high recovery rate
2) Excellent mechanical strength ensures high column efficiency and separation; Low column loss represents long life
3) There are a wide range of products with different pore size parameters, which can meet the separation requirements of proteins, polypeptides, oligonucleotides, cephalosporins and polysaccharides
Minimal nonspecific adsorption
The retention time of lysozyme (sample) on other SEC columns increased significantly with the decrease of buffer concentration in mobile phase, which had strong non-specific adsorption effect of ion exchange. However, the influence on targettm SEC column was very small, which made the protein sample analysis data more accurate and real.
Technical parameters of target™ SEC column
model | Target-SEC150 | Target-SEC300 | Target-SEC500 | Target-SEC1000 |
Material Science | Surface bonded hydrophobia silica gel | Hydrophobia,surface bonding Silica gel of film | Hydrophobia,surface bonding Silica gel of film | hydrophobia surface bonding Silica gel of film |
Particle size | 5µm | 5µm | 5µm | 5µm |
aperture (Å) | 150 | 300 | 500 | 1000 |
Protein molecular weight range(A) | 2K-150K | 10K-1000K | 20K-2000K | 50K-10000K |
Molecular weight range of polyethylene glycerin(A) | 0.1K-15K | 1K-100K | 5K-20K | 10K-100K |
Molecular weight range of dextrose(A) | 1K-50K | 5K-150K | 20K-500K | 50K-2000K |
fstability | 2-8 | 2-8 | 2-8 | 2-8 |
Back pressure | 5000Psi | 5000psi | 5000psi | 5000psi |
Salt concentration range | 20M-2M | 20M-2M | 20M-2M | 20M-2M |
temperature | 45℃ | 45℃ | 45℃ | 45℃ |
application area |
Small,molecule,protein,peptide,nondeductible, saccharine,and,phallocentric,polymer |
Protein,antibody,And,polymer | Protein, antibody And polymer | Protein, antibody, vaccine And polymer |
Mobile phase compatibility | Common buffer And organic solvents | Common buffer And organic solvents | Common buffer And organic solvents | Common buffer And organic solvents |
Some applications
Chromatographic:
1、Target-SEC500 5um 4.6*300mm
2、Target-SEC300 5um 4.6*300mm
3、Target-SEC150 5um 4.6*300mm
Mobile phase:150mM phosphate buffered saline (pH6.8)
Flow rate:0.4ml/min
Temperature:30℃
Injection volume:5ul
Wavelength:UV@280nm
Sample:
1、Thyroglobulin(0.5mg/ml), 670KD
2、Conalbumin(1mg/ml), 75KD
3、Ribonuclease A(1mg/ml), 13.7KD
4、Uracil(0.1mg/ml), 112D
Fusion protein
Chromatographic :Target-SEC500 5um 4.6*300mm
Mobile phase:150mM phosphate buffered saline (pH6.8)
Flow rate:0.4ml/min
Temperature:30℃
Injection volume:5ul
Wavelength:UV@280nm
Sample:Fusion Protein(1mg/ml)
Polyclonal antibody (IgG1)
Chromatographic column:Target-SEC300 5um 4.6*300mm
Mobile phase:150mM phosphate buffered saline (pH6.8)
Flow rate:0.4ml/min
Temperature:30℃
Injection volume:5ul
Wavelength:UV@280nm
Sample:IgG1(2.5mg/ml)
Atlas:1、IgG1 2、IgG1 Aggregate
Polyclonal antibody (IgG4)
Chromatographic :Target-SEC500 5um 4.6*300mm
Mobile phase:150mM phosphate buffered saline (pH6.8)
Flow rate:0.4ml/min
Temperature:30℃
Injection volume:5ul
Wavelength:UV@280nm
Sample:IgG4(2.5mg/ml)
Atlas:peak1:IgG4
peak2-6:IgG4 Aggregates
Human serum albumin and related polymers
Chromatographic :Target-SEC300 5um 4.6*300mm
Mobile phase:150mM phosphate buffered saline (pH6.8)
Flow rate:1.0 ml/min
Temperature:30℃
Injection volume:10ul
Wavelength:UV@210nm
Sample:Human albumin aqueous solution
Atlas:1、Human serum albumin
2、Human albumin dimer
3、Human albumin polymer
Examination of related substances II in Cefodizime Sodium (method 2015 of Chinese Pharmacopoeia)
Chromatographic :Target-SEC150 5um 7.8*300mm
Mobile phase:phosphate buffered saline (pH7.0):Acetonitrile(95:5)
Flow rate1.0 ml/min
Temperature:30℃
Injection volume:20ul
Wavelength:UV@231nm
Sample:Cefodizime sodium(0.5mg/ml)
Atlas:peak1:Cefodizime sodium
peak2-5:Cefodizime sodium polymer
Ceftriaxone sodium polymer test (G10 highly effective alternative sec method in Chinese Pharmacopoeia 2015)
Chromatographic:Target-SEC150 5um 7.8*300mm
Mobile phase:phosphate buffered saline (pH7.0)
Flow rate:1.0ml/min
Temperature:30℃
Injection volume:20ul
Wavelength:UV@231nm
Sample:Ceftriaxone sodium
Atlas:peak1:Ceftriaxone sodium
peak2-5:Ceftriaxone sodium polymer
Target sec series product specifications
product | Pore Size | Particle size | Specifications | Part number |
Target-SEC100 | 100A | 5um | 4.6*300mm | 311330-78030 |
Target-SEC100 | 100A | 5um | 7.8*300mm | 311330-78030 |
Target-SEC150 | 150A | 5um | 7.8*300mm | 311340-78030 |
Target-SEC150 | 150A | 5um | 4.6*300mm | 311340-46030 |
Target-SEC300 | 300A | 5um | 7.8*300mm | 311350-78030 |
Target-SEC300 | 300A | 5um | 4.6*300mm | 311350-46030 |
Target-SEC500 | 500A | 5um | 7.8*300mm | 311360-78030 |
Target-SEC500 | 500A | 5um | 4.6*300mm | 311360-46030 |
Target-SEC1000 | 1000A | 5um | 7.8*300mm | 311370-78030 |
Target-SEC1000 | 1000A | 5um | 4.6*300mm | 311370-46030 |
Chromatographic column selection tips: the 7.8 mmid SEC column is the traditional common specification. If the 4.6 mmid SEC column is selected, it can have higher sensitivity under the condition of limiting the sample size, and can save solvent consumption for your laboratory, which is more economical and environmental friendly.