MS-Clean™C8-SCX-SAX

C8 / SCX octyl / strong cation exchange
Extraction of basic drugs from biological matrix
The functional group of C8 / SCX is composed of Octyl and sulfonic groups,
Double retention: octyl provides moderate hydrophobicity, sulfonic acid
Provides strong cation exchange.
For over adsorption due to C18 and C8 and over retention of SCX
C8 / SCX mixed mode can be used to extract the samples which are strong and difficult to elute
Take the column.
parameter
Specific surface area: 510 m2/g
Average particle size: 40-75μm
Aperture: 70Å
application
-Detection of drugs and metabolites in biological liquids, such as paracetamol
-Testing for drug abuse, such as cocaine, acetylcodeine, morphine, and ketamine
Moderate retention capacity to solve the problem of difficult elution of individual target compounds suitable for the treatment of complex matrix samples such as blood and urine
 
 

Part No

Specification

Number of packages

MSC8SCX1100

100mg/1ml

100 pieces / bag

MSC8SCX3200

200mg/3ml

50 pieces / bag

MSC8SCX3500

500mg/3ml

50 pieces / bag

MSC8SCX6500

500mg/6ml

30 pieces / bag

MSC8SCX61000

1g/6ml

30 pieces / bag

MSC8SCX121000

1g/12ml

20 pieces / bag


C8 / Sax octyl / strong anion exchange
Extraction of acid drugs from biological matrix
The functional group of C8 / Sax is composed of Octyl and quaternary amino groups,
It has double retention effect: octyl provides moderate hydrophobicity, and quaternary amine group
Provides strong anion exchange.
For excessive adsorption due to C18 and C8, and sax retention capacity is too high
C8 / Sax mixed mode can be used to extract the samples which are strong and difficult to elute
Take the column.
parameter
Specific surface area: 510m²/g
Particle size: 40-75μm
Average aperture: 70Å
application
-Detection of drugs and metabolites in biological liquids, such as barbiturates and aryl benzoic acids
1. Detection of drug abuse, such as THC
Moderate retention capacity to solve the problem of difficult elution of individual target compounds suitable for the treatment of complex matrix samples such as blood and urine
 

Part No

Specification

Number of packages

MSC8SAX1100

100mg/1ml

100 pieces / bag

MSC8SAX3200

200mg/3ml

50 pieces / bag

MSC8SAX3500

500mg/3ml

50 pieces / bag

MSC8SAX6500

500mg/6ml

30 pieces / bag

MSC8SAX61000

1g/6ml

30 pieces / bag

MSC8SAX121000

1g/12ml

20 pieces / bag

 

Before:Carb-GCB